Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Orthopedics ; 47(1): e13-e18, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37276441

RESUMEN

Transiliac-transsacral screw fixation is widely used to stabilize unstable posterior pelvic ring injuries. Preoperative radiographic assessment of the safe osseous corridor is necessary because the safe space of sacrum is narrower for transiliac-transsacral screw placement than for traditional iliosacral screw placement. However, the radiographic assessment has rarely been studied in the Taiwanese population. We retrospectively analyzed 100 patients with pelvic computed tomography images and divided them into normal and dysmorphic pelvis groups. To determine the safe osseous space, we recorded cross-section area, cross-sectional diameter of the safe zone (CS-szD), and safe zone width on axial view (Ax-szW) in the S1 to S3 segments. The prevalence of dysmorphic pelvis was 48% among all patients. In the S1 segment, no differences were found in the cross-section area and CS-szD been the two groups. However, the Ax-szW was significantly smaller in the dysmorphic pelvis group. In the S2 segment, the cross-section area, CS-szD, and Ax-szW were all significantly larger in the dysmorphic pelvis group. In the S3 segment, the cross-section area and CS-szD of the normal pelvis group were both significantly smaller. No differences were found in the Ax-szW between the two groups. Based on our findings in a Taiwanese population, S1 was the most suitable segment for transiliac-transsacral screw fixation in a normal pelvis, whereas S2, followed by S3, was most suitable in a dysmorphic pelvis. This study offers surgeons information on identifying the optimal sacral segment for transiliac-transsacral screw placement for each pelvic morphology. [Orthopedics. 2024;47(1):e13-e18.].


Asunto(s)
Huesos Pélvicos , Sacro , Humanos , Sacro/diagnóstico por imagen , Sacro/cirugía , Sacro/anatomía & histología , Huesos Pélvicos/diagnóstico por imagen , Huesos Pélvicos/cirugía , Huesos Pélvicos/lesiones , Ilion/diagnóstico por imagen , Ilion/cirugía , Estudios Retrospectivos , Fijación Interna de Fracturas/métodos , Tornillos Óseos
2.
EFORT Open Rev ; 8(7): 532-547, 2023 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-37395715

RESUMEN

Purpose: Comminuted fractures with poor bone quality in the elderly are associated with poor outcomes. An alternative to open reduction and internal fixation (ORIF) alone, primary or acute total hip arthroplasty (aTHA), allows early mobilization with full weight bearing. In this study, we aim to analyze whether treatment of aTHA with/withtout ORIF (limited ORIF) vs ORIF alone yields better intra-operative results, functional outcomes, and less complications. Methods: PubMed, Cochrane, Embase, and Scopus databases were searched in accordance with the Preferred Reporting Items for Systematic Review and Meta-analysis (PRISMA) guidelines. Random-effects model and 95% confidence intervals were used. The outcomes of interest were surgery time, blood loss, length of hospital stay, Harris hip score (HHS), 36-Item Short Form Survey (SF-36), complication rate, surgical site infection rate, heterotopic ossification rate, reoperation rate, and mortality rate. Results: Ten observational studies with a total of 642 patients (415 ORIF alone and 227 aTHA with/without ORIF) were included in the systematic review. Compared to ORIF alone, aTHA with limited ORIF provided higher HHS (P = 0.029), better physical function (P = 0.008), better physical component summary (P = 0.001), better mental component summary (P = 0.043) in postoperative 1-year SF-36, lesser complication rate (P = 0.001), and lesser reoperation rate (P = 0.000), but however greater bodily pain (P = 0.001) in acetabular fractured elderlies. Conclusions: Acute THA with limited ORIF is favorable alternative to ORIF technique alone. It provided better HHS, physical, and mental component summary in SF-36 and yielded lower complication and reoperation rate compare to ORIF alone.

3.
Orthopedics ; 46(3): 169-174, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37018623

RESUMEN

Previous studies have reported that large fracture fragment with displacement might cause nonunion of femoral shaft fractures. We therefore intended to delineate significant risk factors for developing a nonunion predisposed by a major fracture fragment. We analyzed 61 patients who were operated on using interlocking nails for femoral shaft fractures from 2009 to 2018. We classified patients with modified Radiographic Union Scale for Tibia fractures scores of less than 11 or needing reoperations by 1 year postoperatively as nonunion. We thereafter measured parameters of the displaced fracture fragment and fracture site to identify the significant difference between the union and non-union groups. We also applied the receiver operating characteristic curve to demonstrate a threshold value for the fragment width (FW) ratio. Among 61 patients with complete follow-up, no significant difference was found regarding length, displacement, and angulation of fragments between patients with and without union. Except for higher mean FW (P=.03) and the FW ratio (P=.01) in patients with nonunion, the logistic regression analysis demonstrated that FW ratio significantly affected union (P=.018; odds ratio, 0.21; 95% CI, 0.001-0.522). Although a fracture fragment greater than 4 cm with displacement greater than 2 cm was reported to significantly cause nonunions, our study showed that an FW ratio greater than 0.55 instead of fragment size or displacement was predictive for the occurrence of nonunion adjoining to the fracture site. Fixation of the third fracture fragment should not be ignored for preventing a nonunion. More attention should be paid to achieve a better fixation for a major fracture fragment with an FW ratio greater than 0.55 to avoid the development of non-union following the use of interlocking nail for femoral shaft fracture. [Orthopedics. 2023;46(3):169-174.].


Asunto(s)
Fracturas del Fémur , Fijación Intramedular de Fracturas , Fracturas no Consolidadas , Humanos , Resultado del Tratamiento , Clavos Ortopédicos/efectos adversos , Estudios Retrospectivos , Fracturas no Consolidadas/diagnóstico por imagen , Fracturas no Consolidadas/cirugía , Fracturas no Consolidadas/epidemiología , Curación de Fractura , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/cirugía , Fracturas del Fémur/complicaciones , Fijación Intramedular de Fracturas/efectos adversos
4.
J Chin Med Assoc ; 86(4): 426-430, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36661280

RESUMEN

BACKGROUND: The volar locking plates have been widely used in a variety of distal radius fractures, but they still have several limitations when dealing with small fragments located around the watershed line with widely reported complications. The volar rim fragments play a critical role in radiocarpal joint stability and failing to secure the volar rim fragment usually results in carpal instability, subluxation, or even dislocation. This study investigates clinical outcomes in the use of a novel implant, the Trident distal radial (TDR) locking plate to treat distal radius fracture with the intermedium column edge (lunate fossa volar rim) fragment involvement. METHODS: A retrospective study of 25 patients was conducted, all patients had intermedium column fractures with lunate fossa volar rim involvement and treat with the TDR between January 2016 and December 2019. The clinical assessment outcomes included VAS Pain, PRWE, and DASH scores. Objective measurements included ROM of the injured wrist and grip strength. Final radiographs were used to evaluate radial inclination, volar tilt, ulnar variance, and distal radioulnar joint instability. Secondary operations related to hardware complications were also recorded. RESULTS: The outcome revealed that the mean VAS Pain Score was 1.3, mean DASH score was 10.5, and mean PRWE score was 9.3. Objective measurements revealed good ROM recovery and an 89% gripping strength recovery compared with contralateral hand. Radiographic measurements revealed good maintenance of volar tilt, radial inclination, and mean ulnar variance. There were no complications related to the implant and all fracture sites were union. CONCLUSION: We believe that the TDR provided more stable fixation among distal radial fractures that predominantly involved the intermedial column and volar rim fragment, and allowing early rehabilitation. We could obtain excellent results in the wrist ROM, gripping power, and Pain Score (VAS).


Asunto(s)
Fracturas del Radio , Fracturas de la Muñeca , Humanos , Radio (Anatomía)/cirugía , Fracturas del Radio/cirugía , Estudios Retrospectivos , Fijación Interna de Fracturas/métodos , Placas Óseas , Dolor , Rango del Movimiento Articular , Resultado del Tratamiento
5.
Arch Orthop Trauma Surg ; 143(4): 1965-1972, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35278092

RESUMEN

INTRODUCTION: Open reduction and internal fixation with plates is the most widespread surgery in traumatic pubic symphysis diastasis. However, implant failure or recurrent diastasis was commonly observed during follow-up. The aim of our study was to evaluate the radiologic findings and clinical outcomes. MATERIALS AND METHODS: Sixty-five patients with traumatic pubic symphysis diastasis treated with plating between 2008 and 2019 were retrospectively reviewed. The exclusion criteria were a history of malignancy and age under 20 years. Radiographic outcomes were determined by radiograph findings, including pubic symphysis distance (PSD) and implant failure. Clinical outcomes were assessed according to the Majeed score at the final follow-up. RESULTS: Twenty-eight patients were finally included. Nine patients (32%) experienced implant failure, including four (14%) with screw loosening and five (18%) with plate breakage. Only one patient underwent revision surgery. Postoperatively, a significant increase in PSD was observed at 3 months and 6 months. Postoperative PSD was not significantly different between patients with single plating and double plating, but it was significantly greater in the implant-failure group than in the non-failure group. The Majeed score was similar between patients with single plating and double plating or between the implant-failure group and the non-failure group. Body mass index, number of plates, age, and initial injured PSD were not significantly different between the implant-failure group and the non-failure group. Only a significant male predominance was observed in the implant-failure group. CONCLUSION: A gradual increase in the symphysis distance and a high possibility of implant failure may be the distinguishing features of traumatic pubic symphysis diastasis fixation. The postoperative symphyseal distance achieved stability after 6 months, even after implant failure. Radiographic outcomes, such as increased symphysis distance, screw loosening, and plate breakage, did not affect clinical functional outcomes.


Asunto(s)
Diástasis de la Sínfisis Pubiana , Sínfisis Pubiana , Femenino , Humanos , Masculino , Adulto Joven , Adulto , Diástasis de la Sínfisis Pubiana/diagnóstico por imagen , Diástasis de la Sínfisis Pubiana/cirugía , Estudios Retrospectivos , Fijación Interna de Fracturas , Sínfisis Pubiana/diagnóstico por imagen , Sínfisis Pubiana/cirugía , Placas Óseas
6.
Sci Rep ; 12(1): 9587, 2022 06 10.
Artículo en Inglés | MEDLINE | ID: mdl-35688938

RESUMEN

This study aims to investigate whether an augmented wire in the treatment of patella distal pole fracture could improve knee range of motion (ROM) and radiographic features. Thirty-five consecutive patients with patellar distal pole fracture were analyzed from January 2014 to July 2019. The treatment is divided into two groups according to the presence or absence of augmented wire. Knee ROM, bone union, extension lag, and patellar height were compared between these two groups as the clinical and radiological outcomes. There was no significant difference in mean knee ROM (110° vs. 108°, p = 0.79), proportion of patella baja or bone union. More extension lag was noted in the augmentation group (5/20, 25%) than in the tendon reattachment group (1/15, 6.7%) with no statistically significant difference. In the augmentation group, four cases (20%) would need to remove the fixator due to irritation or broken hardware. Maintaining the patella length by preserving the distal pole and repairing the torn retinaculum allowed early motion to avoid knee stiffness safely without augmentation wire, which doesn't improve knee ROM. The patellar tendon reattachment alone could achieve a great recovery and prevent the need for a second surgery due to broken wire or irritation.


Asunto(s)
Fracturas Óseas , Traumatismos de la Rodilla , Ligamento Rotuliano , Hilos Ortopédicos , Fracturas Óseas/cirugía , Humanos , Traumatismos de la Rodilla/cirugía , Rótula/cirugía , Ligamento Rotuliano/cirugía , Rango del Movimiento Articular , Estudios Retrospectivos , Resultado del Tratamiento
7.
Hu Li Za Zhi ; 69(2): 32-43, 2022 Apr.
Artículo en Chino | MEDLINE | ID: mdl-35318631

RESUMEN

BACKGROUND: Osteoarthritis is a common cause of inactivity and reduced quality of life in the elderly. Total knee replacement (TKR) surgery, a last-stage treatment option for osteoarthritis, often results in postoperative pain that influences knee flexion and the ability to perform prescribed rehabilitation exercises. PURPOSE: This study was designed to examine the effectiveness of single femoral nerve block (FNB) on pain level and knee mobility in patients with TKR. METHODS: A quasi-experimental, two-group, longitudinal study was designed. The participants were distributed into the FNB group (n = 86) and non-FNB group (n = 86). The outcome measurements included pain scale (Numerical Rating Scale) score and knee continuous passive motion knee flexion angle. The five assessments and followed-up times were as follows: admission day (T0) and post-surgery day 1, 2, 3, and 4. RESULTS: The results of the generalized estimating equations model showed that the pain level in the FNB group was significantly lower than in the non-FNB group, (p < .001). In terms of analgesics demand from post-surgery day 1 to day 4, the FNB group exhibited a significantly lower demand than the non-FNB group (p < .01). In addition, significant differences in the continuous passive motion rehabilitation exercise angle were found between the two groups from post-surgery day 1 through day 4 (p < .05). Finally, significant differences in knee flexion angles between the two groups were observed between hospital admission and discharge (p < .001). CONCLUSIONS / IMPLICATIONS FOR PRACTICE: The findings of this study support the positive effects of the femoral nerve block intervention on patients who receive total knee replacement surgery. The results were significant in terms of pain relief and knee mobility recovery. This intervention should be made available for use in the clinical care of TKR patients.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Bloqueo Nervioso , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/rehabilitación , Nervio Femoral , Humanos , Estudios Longitudinales , Bloqueo Nervioso/efectos adversos , Bloqueo Nervioso/métodos , Dolor Postoperatorio/tratamiento farmacológico , Dolor Postoperatorio/etiología , Calidad de Vida
8.
BMC Musculoskelet Disord ; 23(1): 18, 2022 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-34980102

RESUMEN

INTRODUCTION: The volar locking plate has been widely used for unstable distal radius fractures to provide early recovery of wrist function. Volar plate prominence to the watershed line has been reported to be related to flexor tendon irritation, and avoid implant prominence in this area was suggested. On the other hand, marginal distal radius fracture patterns required the plate to cross the watershed line, making conflict over plate positioning on marginal distal radius fractures. This study compared functional outcomes in patients with marginal distal radius fractures treated with two different implants. MATERIALS AND METHODS: A retrospective study was conducted, all patients who received a Synthes 2.4 mm LCP or an Acumed Acu-Loc VLP between January 2015 and December 2018 were reviewed. The marginal distal radius fracture pattern was the most distal horizontal fracture line within 10 mm of the lunate fossa's joint line. The primary outcomes including patient-reported pain scores, range of motion, and grip strength were assessed. Secondary outcomes included patient-based subjective satisfaction scores of the injured wrist and hand function. The Mayo Wrist Score and the requirement for a secondary procedure related to hardware complications were also recorded. RESULTS: Forty-two patients met our inclusion criteria. Twenty-one patients were treated with the Synthes 2.4 mm LCP, and 21 patients with the Acumed Acu-Loc VLP. The primary outcome revealed that post-operative range of motion (P = 0.016) and grip strengths (P = 0.014) were significantly improved in the Acu-Loc VLP group. The MAYO wrist score in the Acu-Loc VLP group was also significantly better (P = 0.006). CONCLUSIONS: Despite advances in implant designs, flexor tendon irritation or rupture is still a complication following distal radius's volar plating. We believe the Acumed Acu-Loc VLP design provided better functional outcomes than the Synthes 2.4 mm LCP if appropriately and carefully placed into its designed-for position. This positioning results in promising patient satisfaction when treating marginal distal radius fractures.


Asunto(s)
Fracturas del Radio , Placas Óseas , Fijación Interna de Fracturas/efectos adversos , Humanos , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía , Rango del Movimiento Articular , Estudios Retrospectivos , Articulación de la Muñeca/diagnóstico por imagen , Articulación de la Muñeca/cirugía
10.
J Chin Med Assoc ; 85(2): 222-227, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34643618

RESUMEN

BACKGROUND: Terrible triad of the elbow injury is difficult to manage, and the role of the coronoid process in instability is very important. We describe a simple, modified suture technique to fix a coronoid process fragment using suture anchor fixation. METHODS: Eight patients (three female and five male) with coronoid process injuries with the fragment involving <50% of the total height (Regan-Morrey type I/II) in terrible triad of elbow injury were included. Patients were treated operatively via a lateral Kocher's approach, and coronoid process fractures were repaired with a single pulley double-strand suture technique. Structures were addressed in a sequential fashion-the coronoid process, radial head, lateral ulnar collateral ligament. RESULTS: All patients were treated with the single pulley double-strand anchor suture technique and the coronoid process fragment was found to be in good contact with the original avulsion site using the method. The final Mayo Elbow Performance Score was excellent (> 90) in six patients and good (between 85 and 89) in two patients after operation 6 months. CONCLUSION: The single pulley double-strand suture tie method using a suture anchor is a less invasive and simpler fixation method for the repair of coronoid process fractures in patients with terrible triad of the elbow injuries and results in good outcomes.


Asunto(s)
Lesiones de Codo , Articulación del Codo/cirugía , Fijación Interna de Fracturas/métodos , Anclas para Sutura , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
11.
Sci Rep ; 11(1): 21158, 2021 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-34707109

RESUMEN

Negative pressure wound therapy (NPWT) is usually applied in wound management and soft-tissue salvage after the development of complications. However, immediate postoperative application of NPWT over the flap coverage is seldom reported. We evaluate the effectiveness of immediate postoperative application of NPWT following fasciocutaneous or muscle flap coverage for lower leg reconstruction. A retrospective review of patients who underwent either fasciocutaneous or muscle flap coverage of lower leg soft-tissue defects applied with NPWT immediately after surgery was conducted in a level I trauma center. Sixteen patients, with an average age of 51.2 years, were included in the study. Nine patients had trauma-related soft-tissue loss, six had subsequent soft-tissue defects after debridement, and one had burn injury. Two patients had been treated with free anterolateral thigh flaps, 11 with pedicle flaps, and three with muscle flaps. All flaps survived except for those in two patients with venous congestion on postoperative day 1, which needed further debridement and skin grafting. Therefore, the use of immediate incisional NPWT is an alternative for wound care following flap coverage. The U-shaped design allows easy flap observation and temperature check. Furthermore, this method eliminates any concerns of vascular pedicle compression under negative pressure.


Asunto(s)
Pierna/cirugía , Terapia de Presión Negativa para Heridas/métodos , Procedimientos de Cirugía Plástica/métodos , Colgajos Quirúrgicos/cirugía , Adulto , Anciano , Femenino , Humanos , Hiperemia/epidemiología , Hiperemia/etiología , Masculino , Persona de Mediana Edad , Músculo Esquelético/cirugía , Terapia de Presión Negativa para Heridas/efectos adversos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Procedimientos de Cirugía Plástica/efectos adversos
12.
Clin Orthop Surg ; 13(3): 366-375, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34484630

RESUMEN

BACKGROUD: Coracoacromial ligament transfer is the traditional procedure for treating chronic acromioclavicular separation, but it is significantly inferior to ligament reconstruction according to biomechanical and clinical studies. However, ligament reconstruction carries the risk of complications of graft loosening and peri-tunnel fractures. Currently, there is no ligament reconstruction procedure optimal for preventing such complications. The purpose of this study was to describe and retrospectively analyze the clinical and radiological outcomes of a "duo-figure-8" autogenic graft wrapping technique, which was used to concomitantly reconstruct the acromioclavicular and coracoclavicular ligaments. METHODS: Preoperative, immediate postoperative, and final follow-up oputcomes were evaluated in 10 enrolled patients. Radiographic outcomes were indicated by the bilateral difference of the coracoclavicular distance (CCD) and overlapping length of the acromioclavicular joint (OLac). Quality of reduction was classified into 4 grades according to bilateral CCD difference into overreduction (< 0 mm), anatomic reduction (0-4 mm), partial loss of reduction (4-8 mm), and recurrent dislocation (> 8 mm). Clinical outcomes were evaluated using the American Shoulder and Elbow Surgeons (ASES) and Constant scores. RESULTS: The mean side-to-side differences for CCD were 11.9 mm (preoperative), -0.1 mm (immediate postoperative), and 3.4 mm (final follow-up); those for OLac were 9.4 mm (preoperative) and 2.7 mm (final follow-up). CCD and OLac outcomes significantly improved at final follow-up (p < 0.05). At the immediate postoperative stage, 6 and 4 patients had overreduction and anatomic reduction, respectively. At final follow-up, 7 and 3 patients had anatomic reduction and partial loss of reduction, respectively. The magnitude of improvement of ASES scores for patients with anatomic reduction and partial loss of reduction (p = 0.20) was 18.1 and 20.0, respectively. The magnitude of improvement of Constant scores in patients with anatomic reduction and partial loss of reduction (p = 0.25) was 19.9 and 22.3, respectively. CONCLUSIONS: The technique yielded acceptable functional outcomes in patients with anatomic reduction or partial loss of reduction. The "duo-figure-8" wrapping method-a single autogenic tendon graft passing beneath the coracoid process with a tendon-knot fixation over the distal clavicle and looping around the acromion intramedullary-did not increase the risk of peri-tunnel fractures over the clavicle, coracoid process, or acromion.


Asunto(s)
Articulación Acromioclavicular/lesiones , Articulación Acromioclavicular/cirugía , Tendones Isquiotibiales/trasplante , Luxaciones Articulares/cirugía , Ligamentos Articulares/lesiones , Ligamentos Articulares/cirugía , Procedimientos de Cirugía Plástica/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
13.
Medicine (Baltimore) ; 100(17): e25708, 2021 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-33907153

RESUMEN

ABSTRACT: The aim of this study was to evaluate the risk factors related to osteosynthesis failure in patients with concomitant ipsilateral femoral neck and shaft fractures, including old age; smoking habit; comminuted fragments; infra-isthmus fracture; angular malreduction; unsatisfactory reduction (fracture gap >5 mm); and treatment with single construct.Patients over the age of 20 with concomitant ipsilateral femoral neck and shaft fractures diagnosed at a level one medical center between 2003 and 2019 were included. Treatment modalities included single construct with/without an antirotational screw for the neck and dual constructs. Radiographic outcomes were assessed from anteroposterior and lateral hip radiographs at follow-up. Fisher exact test was used to analyze categorical variables. The presence of avascular necrosis of the femoral head, delayed union, atrophic or hypertrophic nonunion of the femoral shaft fracture, and loss of reduction were identified as factors related to treatment failure.A total of 22 patients were included in this study. The average age was 58.5 years, and the majority was male (68.2%). The minimum radiographic follow-up duration was 12 months, and the median follow-up time was 12 (interquartile range 12-24) months.Femoral neck osteosynthesis failed in 3 patients, whereas femoral shaft osteosynthesis failed in 12 patients. Fisher exact test demonstrated the failure of femoral shaft osteosynthesis was significantly more frequent in the single-construct cohort in 16 infra-isthmus femoral fracture cases (P = .034).In ipsilateral femoral neck and infra-isthmus shaft fractures, it is better to treat the neck and shaft fractures with separate implants (dual constructs).In a dual-construct cohort, separate plate fixation of the femoral shaft achieved a better result in terms of bone union than retrograde nailing of the shaft (bone union rate: 4/8 vs 0/2).


Asunto(s)
Fracturas del Fémur , Fracturas del Cuello Femoral , Fijación Intramedular de Fracturas , Fijadores Internos , Complicaciones Posoperatorias , Cuidados Posteriores/métodos , Femenino , Fracturas del Fémur/diagnóstico , Fracturas del Fémur/epidemiología , Fracturas del Fémur/cirugía , Fracturas del Cuello Femoral/diagnóstico , Fracturas del Cuello Femoral/epidemiología , Fracturas del Cuello Femoral/cirugía , Fijación Intramedular de Fracturas/efectos adversos , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Fracturas Conminutas/diagnóstico , Fracturas Conminutas/epidemiología , Fracturas Conminutas/cirugía , Humanos , Fijadores Internos/normas , Fijadores Internos/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Radiografía/métodos , Estudios Retrospectivos , Medición de Riesgo/métodos , Medición de Riesgo/estadística & datos numéricos , Factores de Riesgo , Taiwán/epidemiología , Insuficiencia del Tratamiento
14.
J Chin Med Assoc ; 84(6): 644-649, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33742990

RESUMEN

BACKGROUND: Plate and locked intramedullary nailing for humeral fractures are golden standard procedure, but the humerus is a nonweight-bearing bone and can tolerate a larger range of acceptable alignment. We believe the elastic stable intramedullary nails (ESINs) can provide enough relative stability for humeral shaft fractures in certain adult patients. METHODS: There are four new indications for using ESINs: (1) patient could not tolerate a sugar-tong splint but was a high risk for general anesthesia, (2) intramedullary canal narrowing (<7 mm), (3) long spiral or oblique fracture over the metadiaphyseal junction, and (4) obesity. All patients received retrograde fixation with two titanium elastic nails, except for one patient with a long spiral fracture over the proximal metadiaphysis. Patients had routine follow-up plain radiographs until bone union, and we evaluated functional results of patients by Mayo Elbow Performance Score and asked to complete Quick Disabilities of the Arm, Shoulder and Hand score at the last outpatient clinic visit. RESULTS: A total of 16 patients with a mean age of 54.4 years were included. The mean follow-up time was 14 ± 2.5 months, and the average time to bone union was 16 ± 4.3 weeks. There were no wound infections, loss of reduction, fracture nonunion, implant failure, or skin irritation expect for one nail back-out because of osteoporosis. CONCLUSION: We have reported good results using ESINs for the displaced fractures of the humerus in the four indication adults who would not be able to tolerate plate fixation or intramedullary nailing. The ESINs fixation method is a simple procedure that provides a small incision, minimal blood loss, short surgical time, and relative stability fixation.


Asunto(s)
Clavos Ortopédicos , Fijación Intramedular de Fracturas/métodos , Fracturas del Húmero/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
15.
J Chin Med Assoc ; 84(5): 528-535, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33595994

RESUMEN

BACKGROUND: Although external fixator is standard for managing staged treatment of open tibial fracture, the main disadvantage of this device is too bulky to be tolerated by most patients for longtime use. The purposes of this pilot study were to compare the biomechanical properties of a novel low-profile external fixator (LP-ESF) with a traditional ESF and also to evaluate its performance in patients with Gustilo type IIIb tibial open fractures. METHODS: A prospective clinical pilot study started from January 2015 to December 2017, and 18 patients with Gustilo type IIIb open tibial fractures underwent the fixation with a novel LP-ESF system. The biomechanical properties of the LP-ESF were compared with the Synthes External Fixation System according to the standard ASTM F1541-02. These patients were divided into two groups according to the size of bony defect. The postoperative clinical outcomes were subsequently collected. RESULTS: The biomechanical properties of the LP-ESF were comparable with those of Synthes External Fixation System and had an improved the axial/torsional stiffness and ultimate strength. In the clinical study, all patients with LP-ESF had fracture union. The duration of application of LP-ESF was 3.5 to 18 months until fracture union. In 10 of 18 patients, their fractures were immobilized with the LP-ESF until bone union, and no pin tract infection and no chronic osteomyelitis were recorded. The 36-Item Short Form Health Survey life quality and health survey were good to excellent in these patients. Notably, the LP-ESF allowed a patient with severe bone and soft-tissue defects to preserve the leg and joints function. CONCLUSION: In this study, we found that the novel LP-ESFs had improved clinical outcomes. The long-term LP-ESF application seems to be tolerable in our patients. This novel approach permits better controls in deep infection and faster healing of fractures, and thus may provide a viable alternative treatment for Gustilo type IIIb open tibial fractures.


Asunto(s)
Fijación de Fractura/instrumentación , Fracturas Abiertas/cirugía , Fracturas de la Tibia/cirugía , Fenómenos Biomecánicos , Humanos , Proyectos Piloto , Estudios Prospectivos
16.
Eur J Orthop Surg Traumatol ; 31(1): 71-78, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32715326

RESUMEN

BACKGROUND: Tibial plateau fractures (TPFs) are the most common among periarticular fractures. Mechanism of injuries is most from varus/valgus and flexion injury. Hyperextension type injuries are rare and easily to be overlooked. We reported 12 cases of this fracture type. Complications of early cases were reported, and treatment strategies of late cases were suggested. MATERIALS AND METHODS: From 2010 to 2016, we performed a retrospective analysis of 248 cases of TPFs in our institute and 12 cases of hyperextension bicondylar TPFs were diagnosed. Diagnostic method is from both plain films and CT scans. The features of this injury included sagittal plane malalignment with loss of the normal posterior slope of the tibial plateau, tension failure of the posterior cortex, and compression of the anterior cortex. Surgical approach is predominantly via an anterolateral and/or posteromedial double incision at the first. Then anteromedial with adequate grafting to support the bone defect was modified. Postoperative radiographic analysis, physical examination findings, and complications were reported. Patient reported outcome scores from the Knee Injury and Osteoarthritis Outcome Score (KOOS) were recorded. RESULTS: Twelve patients were followed up for a mean period of 16.6 months (range 12-26 months). The mean time to radiographic bony union was 3.6 months (range 3-9 months, SD 8.5). About complications, the incidence of popliteal artery occlusion received PTA was 8% (1/12). And 3/12 (25%) patients had either partial or complete peroneal nerve injury. 2/12 (16%) patients developed a leg compartment syndrome. 33% (4/12) demonstrated associated injuries including posterolateral complex injuries mostly and posterior cruciate ligament avulsion fracture in one case. The average range of motion of the affected knees was 3.4-130° postoperatively. Analysis of complication about surgery included inadequate reduction and fixation in two cases, insufficient bone grafting in one case. The mean mPTA was significantly improved after fixation (preoperative 82° postoperative 3 months 86°). The mean posterior slope (PTA) was preoperative  - 3° and postoperative 3 months 3°. And mean KOOS was 80. CONCLUSIONS: Hyperextension bicondylar tibial plateau fractures show a special characteristic of changes in posterior tibial slope angle and are easy to be overlooked. Complication rate is high after injury and after ineffective fixation. Choosing correct approach with sufficient grafting and stable fixation for treatment of hyperextension bicondylar tibial plateau fractures should be used to improve patients' outcome.


Asunto(s)
Fijación Interna de Fracturas , Fracturas de la Tibia , Adolescente , Adulto , Femenino , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Humanos , Fracturas Intraarticulares/complicaciones , Fracturas Intraarticulares/diagnóstico por imagen , Fracturas Intraarticulares/cirugía , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/prevención & control , Rango del Movimiento Articular , Estudios Retrospectivos , Tibia/lesiones , Tibia/cirugía , Fracturas de la Tibia/complicaciones , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Resultado del Tratamiento
17.
Orthopedics ; 43(5): e359-e363, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32602920

RESUMEN

Clavicle hook plate is a common implant for treating distal clavicle fracture. Although high bone union rate and good functional outcome have been reported, so have several complications, such as osteolysis and fracture of the acromion, loss reduction, hook impingement, and rotator cuff tear. Peri-implant fracture over the medial side of the hook plate is a rare complication. Sporadic cases have been reported, and most of them have had no history of trauma. Between June 2015 and August 2018, 7 patients treated for distal clavicle fracture with a 3.5-mm locking compression hook plate with no history of trauma experienced peri-implant fracture of the medial clavicle. This complication occurred at a mean of 29 days. The incidence rate was 9.8%. Peri-implant fracture following hook plate fixation for distal clavicle fracture was not rare. Small hook angle, prolonged retention of the implant, an eccentric medial screw, high plate screw density, and small clavicle diameter may be risk factors for peri-implant fracture. Regarding treatment, 2 patients chose fracture revision with a distal clavicle locking plate and 5 patients chose conservative treatment. All patients achieved bone union at fracture sites. Surgical and conservative management of peri-implant fracture can achieve good functional outcome. [Orthopedics. 2020;43(5);e359-e363.].


Asunto(s)
Placas Óseas/efectos adversos , Clavícula/lesiones , Fijación Interna de Fracturas/efectos adversos , Fracturas Óseas/cirugía , Fracturas Periprotésicas/etiología , Tornillos Óseos , Clavícula/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fracturas Periprotésicas/cirugía , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Adulto Joven
18.
Injury ; 51(8): 1805-1811, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32507454

RESUMEN

INTRODUCTION: Soft tissue swelling after acute fracture surgery is a challenge which may increase wound dehiscence, delay early range of motion, and increase infection rate postoperatively. This study investigates closed incision negative pressure therapy (ciNPT) using wide-range cover over the incision site and the peripheral swelling trauma zone to promote early active motion and to mitigate joint stiffness, bulla formation, and tendon adhesion. METHODS: Twenty-nine patients were enrolled between January 2018 and December 2018. Patients with high-energy soft tissue trauma and comminuted fractures over distal end of limbs (hand and foot; wrist and ankle) or muscle scarcity areas (tibial shaft or patella) were included. ciNPT was applied over closed incisions in the operating room and subatmospheric pressure (-125 mmHg) initiated continuously for 5~7 days. RESULTS: In hand and foot patients (n= 8), active motion over all fingers or toes occurred after post-operative Day 2. Mild swelling without any bullous formation was observed over the dorsal aspect of hand. In wrist and ankle patients (n= 16), flexion angle over the finger joints over 90 degrees was observed after 5 days post-surgery. For patients with tibial shaft comminuted fractures with impending compartment syndrome, early active motion of knee and ankle joint was observed as soft tissue swelling and distension pain had subsided after surgery. CONCLUSION: The prophylactic ciNPT use in the trauma area after surgery reduced postoperative distension pain and improved early range of motion of the tendon and joint in these patients.


Asunto(s)
Fracturas Óseas , Terapia de Presión Negativa para Heridas , Fijación Interna de Fracturas/efectos adversos , Humanos , Rango del Movimiento Articular , Infección de la Herida Quirúrgica , Resultado del Tratamiento
19.
J Int Med Res ; 48(2): 300060519869073, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31510833

RESUMEN

In acute trauma, posterior cruciate ligament (PCL) injury may occur concomitantly with a bony fracture and be easily overlooked. A popliteal artery injury associated with a tibial plateau fracture and PCL avulsion fracture is rare. Missed or delayed diagnosis of this condition leads to a high amputation rate. Therefore, close attention is required with this type of injury. The limb can be saved though early detection and immediate reconstruction of the injured artery, followed by fasciotomy. We report here a rare case of popliteal artery occlusion proximal to the surgical zone, which was diagnosed after fixation of a medial tibial plateau fracture and posterior cruciate avulsion injury. In dashboard injuries without knee dislocation, the arterial intima may be injured and become vulnerable, even with an initial ankle brachial index greater than 0.9. This can cause concomitant occlusion of the popliteal artery due to iatrogenic retraction during surgery. Therefore, a neurovascular examination should be repeated to prevent delayed-onset thrombosis. To the best of our knowledge, this is the first case of popliteal artery injury concomitant with a tibial plateau fracture and PCL avulsion owing to initial dashboard injury-related arterial intima injury, which can present with a normal ankle brachial index.


Asunto(s)
Fracturas por Avulsión , Ligamento Cruzado Posterior , Fracturas de la Tibia , Humanos , Articulación de la Rodilla , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/cirugía , Ligamento Cruzado Posterior/diagnóstico por imagen , Ligamento Cruzado Posterior/cirugía , Fracturas de la Tibia/complicaciones , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía
20.
Injury ; 50(10): 1756-1763, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31543317

RESUMEN

INTRODUCTION: Updated three column fixation of tibial plateau fractures (TPFs) arouse the importance of posterior column articular reduction. Complex TPFs with posterolateral (PL) articular injury is difficult to manage. We presented a strategy of combined positions and approaches to treat these injuries. Surgical technique was described and outcome of these were reported. MATERIALS AND METHODS: From 2014 Jan to 2016 Dec, there were 132 patients of TPFs treated in our institute. Preoperative evaluation included plain films and 2D/3D CT scan to evaluate the involvement of articular surface and associated columns. Inclusion criteria were three column TPFs with PL corner injury. We put patients in prone position first with reverse L incision to manage PL articular impaction and posteromedial (PM) fractures. Then we repositioned the patients in supine to treat anterolateral fixation. Postoperative radiographic analysis, physical examination findings, and patient reported outcome scores from the Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaire were recorded. RESULTS: Patient demographic information was retrospectively reviewed with a mean follow-up time of 34.4 months (range 24-48 months). The average time to union was 5.2 months (range 4-8months). 13/16 (81%) of patients had satisfactory articular reduction by plain films (less than 2 mm articular step off). All patients demonstrated healed without secondary displacement or infection. All patients demonstrated satisfactory coronal (medial proximal tibia angle 84.68 degrees) and sagittal alignment (posterior proximal tibia angle 84.75 degrees). Condylar width averaged 3.93 mm. 3/16 (19%) of cases required posterolateral columnar plating in addition to posteromedial columnar plating. The knee range of motion averaged 115 degrees (ranged from 0 degrees of extension to140 degrees flexion). The average KOOS score was 83/100 (range 76-90). 3 patients in the series developed a surgical site superficial infection and resolved after debridement and oral antibiotics use. No patient eventually received total knee arthroplasty at the last follow up. CONCLUSIONS: Our strategy provides an effective method to treat three column tibial plateau fractures with PL articular injury.


Asunto(s)
Enfermedades de los Cartílagos/cirugía , Cartílago Articular/fisiopatología , Fijación Interna de Fracturas/métodos , Curación de Fractura/fisiología , Posicionamiento del Paciente/estadística & datos numéricos , Fracturas de la Tibia/cirugía , Adulto , Anciano , Enfermedades de los Cartílagos/diagnóstico por imagen , Enfermedades de los Cartílagos/fisiopatología , Cartílago Articular/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular , Estudios Retrospectivos , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...